Data-Linc Group SRM6200E-SLC Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Networking Data-Linc Group SRM6200E-SLC. Data-Linc Group SRM6200E-SLC User guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
USER GUIDE
I
NDUSTRIAL
D
ATA
C
OMMUNICATIONS
It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment.
Discrete/Analog Wireless Multiplexer
DDAA1000/SRM/2.4 GHz
Przeglądanie stron 0
1 2 3 4 5 6 ... 40 41

Podsumowanie treści

Strona 1 - DDAA1000/SRM/2.4 GHz

USER GUIDEINDUSTRIAL DATA COMMUNICATIONSIt is essential that all instructions contained in the User Guide are followed precisely to ensure proper oper

Strona 2 - FCC Notification

DATA-LINC GROUP8PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideAnalog OperationSpecifications1. This unit does not provide loop power to devices.2. Th

Strona 3 - Table of Contents

DATA-LINC GROUP9DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CFigure 7: Connection of a flow meter to the DDAA1000/SRM unitFlow Meter4-20mA Out In fr

Strona 4

DATA-LINC GROUP10PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuidePoint-to-Multipoint Analog SystemUnlike the discrete versions, the system must be conf

Strona 5 - (425) 882-2206

DATA-LINC GROUP11DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CPoint-to-Multipoint Analog OperationA system is to be built where one analog input exi

Strona 6

DATA-LINC GROUP12PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideChanging System or Radio ConfigurationsTo access the system or radio setups the user m

Strona 7 - Connections

DATA-LINC GROUP13DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CTechnical SpecificationsChannelsDD1000/SRM has 8 discrete inputs and 8 discrete output

Strona 8 - DC Supply

DATA-LINC GROUP14PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideTroubleshootingI have the units setup on a bench for testing, but the Master’s status

Strona 9

DATA-LINC GROUP15DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CTechnical SupportData-Linc Group maintains a fully trained staff of service personnel

Strona 10 - Point-to-Point Analog System

DATA-LINC GROUP16PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideAppendix AEnclosure DimensionsTOP4 - 20mA OUTPUTPWRSTATUSCONTACT CLOSURE INPUT8 7

Strona 11 - B A

DATA-LINC GROUP17DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CAppendix BFigure 10: PCB LayoutDDAA1000 - DD1000 ConfigurationThe system configuration

Strona 12 - Factory Configuration Process

DATA-LINC GROUPPN 161-09981-002CProduct User GuideFCC NotificationThis device complies with part 15 of the FCC rules. Operation is subject to the foll

Strona 13 - DATA-LINC GROUP

DATA-LINC GROUP18PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideIf you have the Data-Linc Group PC program DDAAEEprom.exe it is designed to run in Win

Strona 14

DATA-LINC GROUP19DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CThe number of analog values received from a remote is the same as the number of analog

Strona 15 - Technical Specifications

DATA-LINC GROUP20PN 161-10007-002CDDAA1000/SRM/2.4GHz User Guide6. The unit will now ask for the number of ADs (analog inputs) on each Remote. ‘#ADsS

Strona 16 - Troubleshooting

DATA-LINC GROUP21DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CAppendix CRadio ConfigurationThe radio module in the DDAA1000/DD1000 can be set to sui

Strona 17 - Contact Information

DATA-LINC GROUP22PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideWhen the setup program the main menu will appear on the screen. The main menu also dis

Strona 18 - Appendix A

DATA-LINC GROUP23DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CMain Menu Option (0): Set Operation ModeWhen item (0) is selected, the Operation Mode

Strona 19 - Appendix B

DATA-LINC GROUP24PN 161-10007-002CDDAA1000/SRM/2.4GHz User Guide(4) Point-to-Point Remote/Repeater Option 4 allows you to designate the radio mod

Strona 20

DATA-LINC GROUP25DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CMain Menu Option (1): Set Baud RateWhen option (1) is selected you will be able to cha

Strona 21

DATA-LINC GROUP26PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideMain Menu Option (2): Edit Call BookIf the DDAA1000/DD1000 system is only two (2) unit

Strona 22

DATA-LINC GROUP27DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CEntering or Modifying Numbers in the Call BookEntering or modifying call book numbers

Strona 23 - Radio Configuration

DATA-LINC GROUP1DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CTable of ContentsPageIntroduction 3Discrete Operation 5Analog Operation 8Changing Syste

Strona 24

DATA-LINC GROUP28PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideMain Menu Option (3): Edit Radio Transmission CharacteristicsWhen option (3) is select

Strona 25

DATA-LINC GROUP29DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CTable 4: Minimum Packet Size Settings (bytes)Table 5: Maximum Packet Size Settings whe

Strona 26

DATA-LINC GROUP30PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideTable 6: Maximum Packet Size Settings where RF Data Rate=20 1 2 3 4 5 6 7 8 9051638597

Strona 27

DATA-LINC GROUP31DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002C(5) RF Xmit Power The DDAA1000/SRM offers users the ability to modify the Transmi

Strona 28

DATA-LINC GROUP32PN 161-10007-002CDDAA1000/SRM/2.4GHz User Guide(9) Lowpower Mode For DDAA1000/DD1000 use the user should not change this paramet

Strona 29

DATA-LINC GROUP33DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CMain Menu Option (4): Show Radio StatisticsOption (4) in the main menu allows the user

Strona 30

DATA-LINC GROUP34PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideNumber of DisconnectsIf, during the course of performing a link test, the link between

Strona 31

DATA-LINC GROUP35DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CMain Menu Option (5): Edit Multi-Point ParametersFigure 15: Multi-Point ParametersShow

Strona 32

DATA-LINC GROUP36PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideAnother parameter in a multi-point network is (4) DTR Connect. When set at (1), the re

Strona 33

DATA-LINC GROUP37DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CSubNet IDThe DDAA1000/SRM series modems offer a SubNet ID system for use in multi-poin

Strona 34

DATA-LINC GROUP2PN 161-10007-002CDDAA1000/SRM/2.4GHz User Guide

Strona 35

DATA-LINC GROUP38PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideTo back out of the process and not enable the password, hit escape. To set a password,

Strona 36

DATA-LINC GROUP39DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CDDAA1000/SRM and DD1000/SRM Placement LocationsPlacement of your DDAA1000/DD1000 is li

Strona 37

DATA-LINC GROUP3DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CIntroductionThe DDAA1000/SRM and DD1000/SRM are discrete/analog signal multiplexers. Th

Strona 38

DATA-LINC GROUP4PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuideTable 1: LED DescriptionFigure 2: Normal User ConnectionDC.dilosnoeblliwDELsihtkniLFRna

Strona 39

DATA-LINC GROUP5DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CDiscrete OperationRequirements1. The outputs of the units cannot directly drive a relay

Strona 40

DATA-LINC GROUP6PN 161-10007-002CDDAA1000/SRM/2.4GHz User GuidePoint-to-Point Discrete OperationThe following illustrates an example of a point-to-poi

Strona 41

DATA-LINC GROUP7DDAA1000/SRM/2.4GHz User GuidePN 161-10007-002CPoint-to-Multipoint Discrete OperationA multipoint system will involve two or more remo

Komentarze do niniejszej Instrukcji

Brak uwag